GX/CX (Disposable / Single-use packer)

Disposable (Single-use) packers with GX check-valve (tip) developed by GMA. Available for drillhole sizes between Ø44mm and Ø125mm ( (GX-mini Ø28-36mm).

The GX check-valve opens at approx. 2 Bar pressure, and does not require back pressure to close after injection. GX packers are available in both low-pressure and high-pressure versions, read more about each packer under "Product variants" below.

 

Product variants

Low-pressure packers for injection pressures up to approx. 65 Bar (depending on packer dimensions, possible injection pressure decreases with increased diameter).

Low-pressure packer is equipped with 3 or 5 locking washers. These lock washers are sized to withstand the maximum specified injection pressure after the injection pipe is dismantled. However, consideration of the packer's friction against the rock must be observed when removing injection pipes.

Suitable injection tubes are "Mechanical Low Pressure 1/2"Pipes"  or "Manual 1/2" Pipes".

The table below shows: GMA's part number, GMA's model designation, What drillhole diameter the packer is intended for, What diameter the packer has before tensioning, What work span (sealing aperture) the packer has, What connection it is on the thread  on the packer tube and tube dimension on ditto, Which approximately tightening torque required and approximate Maximum injection pressure*, #.

If more information is desired, we refer to the Technical data sheet (TDS) which is available as a PDF file to read/download.

* NOTE: Consideration must be given to rock type and hole direction to finalize maximum injection pressure. The table only shows what the packer itself can handle.

# Packer over diameter 70mm can be equipped with an extra HD lock washer (high pressure washer) if requested by the customer. However, doing that requires HD type injection tubing and should not be confound (mixed up) with HD packers (it is still a Low Pressure Packer).

 

Piranha.Extend.Fields.StringField

GMA    part nr.

GMA Model        

 

Drillhole Ø (mm)    

Outside Ø packer (mm)

Work span
(mm)

 

Thread/dim.  packer tube (Inch /mm)               

Tightening torque (Nm)   

Max injection  pressure   (Bar)

8000845 GX45  (CX45) 45 42,5 44-47 1/2"  (25x3) 90-120 65
8000848 GX48  (CX48) 48 45,5 46-50 1/2"  (25x3) 100-120 65
8000851 GX51 (CX51) 51 48,5 50-53 1/2" (25x3) 100-120 65
8000854 GX54 (CX54) 54 51,5 53-56 1/2" (25x3) 100-120 50
8000857 GX57 (CX57) 57 54,5 56-59 1/2" (25x3) 100-120 50
8000860 GX60 (CX60) 60 57,5 59-62 1/2" (25x3) 100-120 50
8000863 GX63 (CX63) 63 60,5 62-65 1/2" (25x3) 100-120

50

8000866 GX66 (CX66) 66 63,5 65-69 1/2" (25x3) 120-150 40
8000870 GX70 (CX70) 70 67,5 69-75 1/2" (25x3) 120-150 40
8000875 GX75 (CX75) 75 72,5 74-79 1/2" (25x3) 120-150 35
8000880 GX80 (CX80) 80 77,5 79-84 1/2" (25x3) 120-150 30
8000885 GX85 (CX85) 85 82,5 84-89 1/2" (25x3) 120-150 30
8000890 GX90 (CX90) 90 87,5 89-94 1/2" (25x3) 120-150 25
8000895 GX95 (CX95) 95 92,5 94-99 1/2" (25x3) 120-150 25
80008100 GX100 (CX100) 100 97,5 99-104 1/2" (25x3) 140-160 20
80008102 GX102 (CX102) 102 99,5 101-105 1/2" (25x3) 140-160 20
80008105 GX105 (CX105) 105 102,5 104-109 1/2" (25x3)

140-160

20
80008110 GX110 (CX110) 110 107,5 109-114 1/2" (25x3) 140-160 15
80008115 GX115 (CX115) 115 112,5 114-119 1/2" (25x3) 140-160 15
80008120 GX120 (CX120) 120 117,5 119-124 1/2" (25x3) 140-160 10
80008125 GX125 (CX125) 125 122,5 124-130 1/2" (25x3) 140-160 10

 

High-pressure packer for injection (grouting) pressures up to approx. 100 Bar.

High-pressure packers are equipped with 5 std. lock washers and an extra high-pressure washer (HD washer). These lock washers are sized to withstand the maximum specified injection pressure after the injection pipe is dismantled. In addition to internal development and testing of high-pressure packers, tests have also been made of GMA's HD packers at 3rd party (DNV Norway).

GMA's high-pressure packers require adapted injection pipes, so-called "HD-Injection pipes for mechanical mounting" which are adapted not to damage the HD lock washer during tightening and equipped with a rotating safety hook and ball valve for high pressures.

The table below shows: GMA's part number, GMA's model designation, What drillhole diameter the packer is intended for, What diameter the packer has before tensioning, What work span (sealing aperture) the packer has, What connection it is on the thread  on the packer tube and tube dimension on ditto, Which approximately tightening torque required and approximate Maximum injection pressure*, #.

If more information is desired, we refer to the Technical data sheet (TDS) which is available as a PDF file to read/download.

* NOTE: Consideration must be given to rock type and hole direction to finalize maximum injection pressure. The table only shows what the packer itself can handle. In cases where there is bad rock, high pressure packers with mechanical locking are also available, see section "Special packers high pressure flow"

# HD-packers are supplied for drill holes between 48mm up to 66mm. This is based on the size of the HD washer and performed tests. In the event that injection tubes are not removed immediately after injection, other injection pressures and larger diameters can be used if necessary, but then do not fall within GMA's definition for an HD packer.

 

Piranha.Extend.Fields.StringField

GMA

Part nr.

GMA Model        

 

Drillhole  Ø (mm)    

Outside Ø packer (mm)

Work span 
(mm)

 

Thread/dim.  packer tube (Inch /mm)               

Tightening torque

(Nm)   

Max   injection pressure

(Bar)

8000848HD GX48HD (CSX48) 48 45,5 46-50 1/2"  (25x3) 120-150 90-100
8000851HD GX51HD (CSX51) 51 48,5 50-53 1/2" (25x3) 120-150 90-100
8000854HD GX54HD (CSX54) 54 51,5 53-56 1/2" (25x3) 120-150 90-100
8000857HD GX57HD (CSX57) 57 54,5 56-59 1/2" (25x3) 120-150 90-100
8000860HD GX60HD (CSX60) 60 57,5 59-62 1/2" (25x3) 120-150 90-100
8000863HD GX63HD (CSX63) 63 60,5 62-65 1/2" (25x3) 120-150

90-100

8000866HD GX66HD (CSX66) 66 63,5 65-68 1/2" (25x3) 120-150

80-90

Low-pressure packers for injection pressures up to approx. 65 Bar (depending on packer dimensions, possible injection pressure decreases with increased diameter). 

Low pressure packer is equipped with 3 pcs lock washers and these lock washers are sized to withstand the maximum specified injection pressure after the injection pipe is dismantled. However, consideration of the packer's friction against the rock must be observed when removing injection pipes.

Suitable injection tubes are Manual 3/8" tubes.

The table below shows: GMA's part number, GMA's model designation, What drill hole diameter the packer is intended for, What diameter the packer has before tensioning, What working area (sealing area) the packer has, What connection thread it is on the packer tube and tube dimension on ditto, Which approximately tightening torque required and approximate Maximum injection pressure*.

If more information is desired, we refer to the Technical data sheet which is available as a PDF file to read/download.

* NOTE: Consideration must be given to rock type and hole direction to finalize maximum injection pressure. The table only shows what the packer itself can handle.

 

Piranha.Extend.Fields.StringField

GMA Part nr.

GMA

Model        

Bore hole Ø

 Outside Ø packer (mm)

Work span
(mm)

 

Thread/dim.

(Inch/mm) 

 Tightening torque (Nm)

Max injection pressure (Bar)

8000828 GX28  28 27 27,5-30 3/8" (20x25) 70-100 65
8000830 GX30  30 29 29,5-32 3/8" (20x25) 70-100 65
800032 GX32  32 31 31,5-34 3/8" (20x25) 70-100 65
8000834 GX34  34 33 33,5-36 3/8" (20x25) 90-120

65

8000836 GX36  36 35 35,5-38 3/8" (20x25) 90-120 65